Circulation Devices
Constant-Temperature Water Circulator 1500W
AS ONE Corporation
• Model number: MTC-1500
• Circulation method: Sealed system circulation
• The value is when external circulation capacity (50/60Hz) is at (room temperature 20?, 50Hz, no impact. ) : Maximum flow 40.7/44.6L/min, Maximum head 13.
$0
[Global Model]Forced Convection Oven (Energy Saving) DNE670V
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
$0
Constant-Temperature Water Circulator 3000W
AS ONE Corporation
• Model number: MTC-3000
• Circulation method: Sealed system circulation
• The value is when external circulation capacity (50/60Hz) is at (room temperature 20?, 50Hz, no impact. ) : Maximum flow 40.7/44.6L/min, Maximum head 13.
$0
[Global Model]Forced Convection Oven (Energy Saving) DNE850V
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
$0
[Global Model]Forced Convection Oven (High Temp.) DN411H
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
$0
[Global Model]Forced Convection Oven (High Temp.) DN611H
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
$0
[Global Model]Inert Oven DN411I
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
$0
[Global Model]Inert Oven DN611I
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
• Operating temp. range: RT+15~360?
• Temp. adjustment accuracy: ?0.2? (at 360?) JTM K05
• Temp. fluctuation: 1.2?(at 360?) JIS
• Temp. distribution accuracy: ?3.0?(a
$0
[Global Model]Oven, Natural Convection Type DS411
AS ONE Corporation
• Circulation method: Natural convection
• Operating temp. range: RT+5~260?
• Temp. control accuracy: ?1.0?(at 260?) JTM K05
• Temp. distribution accuracy: ?5.0?(at 260?)
• Max. temp. reaching time: Approx. 70 m
• Operating temp. range: RT+5~260?
• Temp. control accuracy: ?1.0?(at 260?) JTM K05
• Temp. distribution accuracy: ?5.0?(at 260?)
• Max. temp. reaching time: Approx. 70 m
$0
[Global Model]Oven, Natural Convection Type DS611
AS ONE Corporation
• Circulation method: Natural convection
• Operating temp. range: RT+5~260?
• Temp. control accuracy: ?1.0?(at 260?) JTM K05
• Temp. distribution accuracy: ?5.0?(at 260?)
• Max. temp. reaching time: Approx. 90 m
• Operating temp. range: RT+5~260?
• Temp. control accuracy: ?1.0?(at 260?) JTM K05
• Temp. distribution accuracy: ?5.0?(at 260?)
• Max. temp. reaching time: Approx. 90 m
$0
[Global Model]Natural Convection Oven (High Temp., 700?) DR200
AS ONE Corporation
• Circulation method: Natural convection
• Operating temp. range: 300~700?
• Temp. control accuracy: ?5.0?(at 700?) JTM K05
• Temp. distribution accuracy: ?25?(at 700?) JTM K05
• Max. temp. reaching time: Approx
• Operating temp. range: 300~700?
• Temp. control accuracy: ?5.0?(at 700?) JTM K05
• Temp. distribution accuracy: ?25?(at 700?) JTM K05
• Max. temp. reaching time: Approx
$0
[Global Model]Forced Convection Oven (Energy Saving) DNE411
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+20~210?
• Temp. adjustment accuracy: ?0.5?(at210?) JTM K05
• Temp. distribution accuracy: ?2.0?(at210?)JTM K05
• Max. temp. reaching time:
• Operating temp. range: RT+20~210?
• Temp. adjustment accuracy: ?0.5?(at210?) JTM K05
• Temp. distribution accuracy: ?2.0?(at210?)JTM K05
• Max. temp. reaching time:
$0